Skip to content
  • Who We Are
    • About
    • Leadership & Administration
    • Boards and Committees
    • Membership
    • Support SD CFAR
  • Core Services
    • Administrative Core
    • Advanced Technology Core
      • Single-Cell -Omics Unit
      • Flow Cytometry Unit
      • Omics/Epigenetics Unit
    • Biostatistics and Modeling Core
    • Clinical Investigation Core
    • Developmental Core
    • Sociobehavioral Science Core
  • Grants
    • Developmental Grants
      • Developmental Grant Review Committee
    • Developmental x Clinical Investigation Grants
    • Developmental x HWSPH Grants
    • Community Research Kick Start (CRKS) Grant
    • Clinical Research Kick Start (CI-KS) Grant
    • Next Generation Grant
    • Propel Grant
    • Post-Award Responsibilities
  • Education and Events
    • Calendar
    • HIV Education & Training
    • Research Unplugged
    • Research Day
  • Working Groups
  • Resources
    • Cite the CFAR
      • CFAR Logo
      • NIH Public Access Requirements
    • Collaborative Marketplace
    • Grant Writing
      • Training Videos
      • O-K Review
    • Leadership Academy
    • Manuscript Resources
    • SD CFAR Navigator

Flow Cytometry Unit

  1. Home
  2. Cores
  3. Advanced Technology Core
  4. Flow Cytometry Unit

About

Submit a Service Request

The Flow Cytometry Unit facility provides a centralized resource for technical expertise and major equipment. The Unit supports and enhances experimental design and execution of basic and applied research that require flow cytometric cell analysis or cell sorting.

To achieve this objective, the Flow Cytometry Unit offers the following:

  • Expert consultation is provided through the core director, laboratory supervisor, and our senior technical specialists;
  • Cytometry instruments are selected for complementary functions;
  • Equipment use is accessible through dedicated technician-operators;
  • All services are provided on a recharge basis;
  • Assistance with data analysis can be customized to the needs of individual investigators and research projects.

The unit facility contains five major pieces of equipment that perform multiple functions. Current services include: multiparameter analysis (1-6 antibody combinations) on cell suspensions and cells fixed to slides, and small to large volume cell sorting. Types of cell analyses include: cell maturation phenotypes; cell proliferation and activation (cell cycle/DNA content, CFSE dye; calcium flux, CD69, Annexin-V); intra-cellular proteins (cytokines, cell cycle regulators, viral products); quantification of molecular promoters and reporter genes (GFP, beta-gal; FRET).

Live and fixed cell sorting is performed to recover cell subsets, identified with any combination of the above mentioned analysis tools. A specially equipped cell sorter is available for work with live, biohazardous cell samples (experimental protocol requires approval of the Flow Cytometry Unit Lead). We can help with the design of custom flow cytometry protocols. Contact the facility to schedule services.

Address:

Stein Clinical Research Building, 4th Floor
9575 Gilman Drive
La Jolla, CA 92093

Services

Flow Cytometry Unit Services & Instrumentation

  • Analysis – BD CANTO (RUO GREEN)
    • Lasers: Blue-488nm, Red-640nm, Violet-405nm; up to 11 colors
  • Analysis – BD CANTO (RUO ORANGE)
    • Lasers: Blue-488 nm, Red-640nm, Violet-405nm; up to 11 colors
  • Sort – ARIA II (Non-Biohazard sort or Biohazard sort with bioBUBBLE)
    • Lasers: Blue-488nm, YG-561nm, Red-640nm, Violet-405nm; up to 11 colors
    • Bulk Sorting (2 or 4-way sorting)
    • Clone sorting (1 or more cells/well)
    • Biohazardous sorting
  • Sort – Sony MA900 (Non-Biohazard or Biohazard sort)
    • Lasers: Violet 405nm, Blue 488nm, Yellow/Green 561nm, and Red 638nm, up to 12 colors
    • Bulk sorting (2 to 4 populations)
    • Single-cell deposition
    • Biohazardous sorting
  • Sort – WOLF (NanoCellect, Inc.)
    • Gentle sort <2psi
    • Endorsed by 10X Genomics, Inc. for downstream single-cell applications
    • Laser: 488nm; filter configuration: 525+/-25nm (FITC,GFP), 585+/-20nm (PE), 665nm Long Pass (PerCP-Cy5.5)
    • Bulk cell sorting and single-cell deposition (96- and 384-well plates)
  • Training

Core Leadership

Nadejda Beliakova-Bethell, PhD
Nadejda Beliakova-Bethell, PhD
Advanced Technology Core
Associate Director

Questions? Please email cfar@ucsd.edu

UC San Diego logo

UC San Diego, 9500 Gilman Dr.

La Jolla, CA 92093 · (858) 534-2230

© 2026 Regents of the University of California.

center for aids research logo
Accessibility
Privacy
Terms of Use
Go to Top
center for aids research logo
  • Who We Are
    • About
    • Leadership & Administration
    • Boards and Committees
    • Membership
    • Support SD CFAR
  • Core Services
    • Administrative Core
    • Advanced Technology Core
      • Single-Cell -Omics Unit
      • Flow Cytometry Unit
      • Omics/Epigenetics Unit
    • Biostatistics and Modeling Core
    • Clinical Investigation Core
    • Developmental Core
    • Sociobehavioral Science Core
  • Grants
    • Developmental Grants
      • Developmental Grant Review Committee
    • Developmental x Clinical Investigation Grants
    • Developmental x HWSPH Grants
    • Community Research Kick Start (CRKS) Grant
    • Clinical Research Kick Start (CI-KS) Grant
    • Next Generation Grant
    • Propel Grant
    • Post-Award Responsibilities
  • Education and Events
    • Calendar
    • HIV Education & Training
    • Research Unplugged
    • Research Day
  • Working Groups
  • Resources
    • Cite the CFAR
      • CFAR Logo
      • NIH Public Access Requirements
    • Collaborative Marketplace
    • Grant Writing
      • Training Videos
      • O-K Review
    • Leadership Academy
    • Manuscript Resources
    • SD CFAR Navigator